English flagItalian flagGerman flagSpanish flagFrench flagPortuguese flagJapanese flagKorean flagChinese flagRussian flag
By N2H
Home » Tips » Egenera SAN disk errors diagnosis

Egenera SAN disk errors diagnosis

SYMPTOM
br> Repeated errors in /var/log/messages
bash-2.05b# tail /var/log/messages
Aug 16 15:47:26 hostx kernel: SCSI disk error : host 0 channel 0 id 101 lun 0 return code = 10000
Aug 16 15:47:26 hostx kernel: I/O error: dev 44:a1, sector 16
Aug 16 15:47:26 hostx kernel: SCSI disk error : host 0 channel 0 id 101 lun 0 return code = 10000
Aug 16 15:47:26 hostx kernel: I/O error: dev 44:a1, sector 17
Aug 16 15:47:26 hostx kernel: SCSI disk error : host 0 channel 0 id 101 lun 0 return code = 10000

TASK
br> - find out what disk this is and what is wrong with it.

grep “id 101″ /var/log/dmesg
Attached scsi disk sdbw at scsi0, channel 0, id 101, lun 0

bash-2.05b# /sbin/fdisk /dev/sdbw
Unable to read /dev/sdbw

bash-2.05b# /etc/vx/diag.d/vxdmpinq /dev/sdbw
ioctl failed: No such file or directory
VxVM vxdmpinq ERROR V-5-1-8856 /etc/vx/diag.d/vxdmpinq issue_scsi_ioctl: ioctl failed for /dev/sdbw, status = 65536 ERRNO = 1d
VxVM vxdmpinq ERROR V-5-1-8887 /etc/vx/diag.d/vxdmpinq: Error returned from issue_scsi_ioctl

The disk has disappeared - call the storage team.

METHOD2
It would be nice if emc had a version of inq for linux :(

From: Guru
Sent: Thursday, August 16, 2007 3:39 PM

Both pservers are giving the error, so it should be the storage side problem.

Ist server

[root@hostx sg]# df -kl | egrep -i sdbw
/dev/sdbw1 37742320 7680 37734640 1% /data/oracle/DSGDWH60/u07
[root@hostx sg]# /etc/vx/diag.d/vxdmpinq /dev/sdbw1
ioctl failed: No such file or directory
VxVM vxdmpinq ERROR V-5-1-8856 /etc/vx/diag.d/vxdmpinq issue_scsi_ioctl: ioctl failed for /dev/sdbw1, status = 65536 ERRNO = 1d
VxVM vxdmpinq ERROR V-5-1-8887 /etc/vx/diag.d/vxdmpinq: Error returned from issue_scsi_ioctl
[root@hostx sg]# /etc/vx/diag.d/vxdmpinq /dev/sdbw
ioctl failed: No such file or directory
VxVM vxdmpinq ERROR V-5-1-8856 /etc/vx/diag.d/vxdmpinq issue_scsi_ioctl: ioctl failed for /dev/sdbw, status = 65536 ERRNO = 1d
VxVM vxdmpinq ERROR V-5-1-8887 /etc/vx/diag.d/vxdmpinq: Error returned from issue_scsi_ioctl

2nd server

[root@host ~]# /etc/vx/diag.d/vxdmpinq /dev/sdbg1
ioctl failed: No such file or directory
VxVM vxdmpinq ERROR V-5-1-8856 /etc/vx/diag.d/vxdmpinq issue_scsi_ioctl: ioctl failed for /dev/sdbg1, status = 65536 ERRNO = 1d
VxVM vxdmpinq ERROR V-5-1-8887 /etc/vx/diag.d/vxdmpinq: Error returned from issue_scsi_ioctl

Regards,
Guru

Not really sure this is correct.

From pserver output extract

(101.0) Yes Yes (9.0.8.5)

From disk outout

(9.0.8.5) 36.0GB DGC/RAID 5 CK200070700473 dev_unix

On control blade itself,

[root@hostx1 root]# disk -l “9.0.8.5″
ID Capacity Type S/N LPAN
(9.0.8.5) 36.0GB DGC/RAID 5 CK200070700473 dev_unix

Partitions:
Get partition table for disk: (9.0.8.5), failed: Could not read disk Could not read disk

Assignments:
dev_unix (hosty, hostp)